Homes in Havering at a glance
This page summarises 77,922 energy performance certificates (EPCs) for homes in Havering, using the most recent certificate for each home. 56% are rated D or lower.
The median floor area is about 83 m².
Half of these certificates were issued in 2020 or later, so most describe homes as they are now or were within the last few years.
What kinds of homes are here
Terraced homes make up 46% of certificates. Mid-terraces lose less heat through shared walls, but outdoor space can be tight, so where an outdoor unit can go and how it affects neighbours is often the deciding factor.
Who owns the homes here
Of the certificates that record tenure, 66% are owner-occupied homes, so most upgrade decisions here sit with the people who live in them. 20% are privately rented and 14% socially rented.
Walls and insulation
42% of the sampled homes have solid walls. These lose more heat than insulated cavity walls and cannot be filled like a cavity, so options are internal or external wall insulation, which cost more and take more planning. A heat pump can still work in a solid-wall home, but a proper heat-loss survey matters, and it is worth asking installers how they sized the system.
How homes are heated
91% of homes use mains gas, so for most households a heat pump would be replacing a gas boiler. Whether that saves money depends heavily on the electricity and gas price gap, the home's insulation and how efficiently the system runs, so compare itemised quotes rather than headline claims.
Among the homes that are not on gas, electric heating is the most common, at 8% of all homes here. Homes on direct electric or storage heating usually see the biggest change in running costs from a heat pump, because the comparison is with full-price electricity.
When homes were built
63% of homes were built between 1930 and 1975. This era is where unfilled cavity walls and thin loft insulation are most common, so insulation upgrades often come before or alongside any change of heating.
Lofts and windows
28% of homes with a roof of their own have no loft or roof insulation recorded, or less than 100 mm. Loft insulation is usually one of the simpler upgrades, and EPC recommendations work towards about 270 mm. Rooms in the roof and flat roofs are harder and need a closer look.
Almost all homes here are double or triple glazed: 9% have any single glazing recorded.
Energy ratings
Most homes sit in bands C and D, with 15% rated E to G. For those homes the EPC recommendations are a useful check on which upgrades are still outstanding.
Improvements suggested for homes in Havering
Across the 77,922 certificates here, the improvements suggested most often are solar panels for electricity (63%), floor insulation (53%) and solar water heating (52%).
A heat pump is suggested on fewer than 1% of certificates here, which says more about the assessment software than about the homes.
Solar panels for electricity is suggested more often here than across London: on 63% of certificates, against 33%.
Solar water heating is suggested more often here than across London: on 52% of certificates, against 25%.
Ask an installer about solar panels insulation
Heat pump grants in Havering
109 heat pump installations in Havering have had a Boiler Upgrade Scheme grant paid (May 2022 to September 2026).
Uptake has grown: 7 grants were paid in 2022/23 and 35 in 2025/26.
These count grant-funded installations only; heat pumps installed without a Boiler Upgrade Scheme grant are not included. Source: DESNZ Boiler Upgrade Scheme statistics.
Installers in and around Havering
Companies House-registered installers listed for Havering: 17 installers have their registered office in Havering, 2 more say on their own website that they work there and 26 more only name the county it is in on their website. 14 of the 45 mention heat pumps.
The typical firm has been trading for 7 years (the median, from Companies House incorporation dates).
The first listed are AJK Energy Ltd, Q Smart Light Ltd and ZOA Energy Solutions Ltd.
AJK Energy Ltd
Says it fits air source heat pump, solar PV, battery storage, solid wall insulation
Says it holds MCS, TrustMark
Q Smart Light Ltd
Says it fits air source heat pump, solar PV, battery storage, boilers
Says it holds MCS
ZOA Energy Solutions Ltd
Says it fits air source heat pump, solar PV, battery storage, boilers
Says it holds MCS
Essex Eco Ltd
Says it fits air source heat pump, ground source heat pump, solar PV, underfloor heating, boilers
Aston Heating Limited
Crystal Windows & Doors Limited
Says it fits solar PV, battery storage, boilers, cavity wall insulation, solid wall insulation, windows and doors
Says it holds HIES, SafeContractor
Select Solar Ltd
M & K Electrical & Data Limited
CPW Electrical Solutions Limited
Advik Limited
PV Electrical Services Limited
Skcg Services Limited
Foreuk Limited
Greenacres Energy Group Ltd
Says it fits solar PV, battery storage, EV charging
Train the Trade Ltd
Suns Power Ltd
Says it fits solar PV, battery storage, EV charging
4nest Concepts & Solutions Ltd
Solar Simplicity Limited
Says it fits solar PV, battery storage
Says it holds MCS, HIES, NAPIT
Voltorb Limited
Says it fits EV charging
Says it holds TrustMark, NAPIT
Says it fits air source heat pump, ground source heat pump, solar PV, solar thermal, underfloor heating, boilers
Says it holds MCS, RECC, NICEIC, SafeContractor, Which? Trusted Trader, Checkatrade
Says it fits air source heat pump, ground source heat pump, water source heat pump, solar PV, battery storage, EV charging, biomass, underfloor heating, boilers
Says it holds MCS, RECC, NICEIC, Gas Safe, OFTEC
Says it fits air source heat pump, ground source heat pump, solar PV, battery storage, underfloor heating, boilers
Says it holds MCS, NAPIT, Gas Safe, APHC, CHAS
Says it fits air source heat pump, ground source heat pump, air to air heat pump, battery storage, underfloor heating, boilers
Says it holds MCS, TrustMark, HIES
Says it fits air source heat pump, solar PV, battery storage, EV charging, boilers, solid wall insulation
Says it holds MCS, TrustMark, PAS 2035
These are the first 24 of 45: firms that name this area first, then those with a registered office nearby, then those that cover the wider area; heat pump firms and the nearest first within each.
Listed from each firm's own website and from Companies House records (contains public sector information licensed under the Open Government Licence v3.0). Being listed is not a recommendation, and what firms say about themselves has not been checked: ask for an installer's MCS certificate number and consumer code membership before you sign anything.
How Havering compares with London
Flats are less common here than across London: 34% of certificates, against 66%.
Homes built before 1930 are less common here than across London: 8% of certificates, against 30%.
Owner-occupied homes are more common here than across London: 66% of certificates, against 46%.
Advice written for London as a whole may not fit Havering on these points.
Where Havering varies
9 smaller areas within Havering have enough certificates for their own page.
Upminster (RM14) has the highest share of homes with solid walls: 62%, against 42% across Havering.
Havering (RM1) has the highest share of homes not on mains gas: 20%, against 9% across Havering.
Havering (RM1) has the highest share of flats: 55%, against 34% across Havering.
Upminster (RM14) has the highest share of detached or semi-detached homes: 75%, against 48% across Havering.
How Havering ranks within London
Of the 33 London local authorities with a page on this site, Havering has the lowest share of flats (34%).
Grants and support (England)
Boiler Upgrade Scheme: owners of homes in England and Wales, including landlords, can get £7,500 off an air source or ground source heat pump (£2,500 for an air-to-air heat pump) when it replaces fossil fuel heating such as gas, oil, LPG or electric heaters. The installer applies for the grant and it is taken off the price on the quote. Most new builds, social housing and hybrid systems are not eligible, and there is one grant per property.