Homes in Erewash at a glance
This page summarises 37,426 energy performance certificates (EPCs) for homes in Erewash, using the most recent certificate for each home. 59% are rated D or lower.
The median floor area is about 78 m².
Half of these certificates were issued in 2019 or later, so most describe homes as they are now or were within the last few years.
What kinds of homes are here
Detached and semi-detached homes account for 69% of certificates. These usually have room for an outdoor heat pump unit and a cylinder, but more exposed wall and roof area means insulation quality has a large effect on how well a heat pump performs.
Who owns the homes here
Tenure is mixed: of the certificates that record it, 64% are owner-occupied, 17% privately rented and 19% socially rented. Who can approve an upgrade differs between those groups, so it is worth knowing which applies before asking for quotes.
Walls and insulation
35% of the sampled homes have solid walls. These lose more heat than insulated cavity walls and cannot be filled like a cavity, so options are internal or external wall insulation, which cost more and take more planning. A heat pump can still work in a solid-wall home, but a proper heat-loss survey matters, and it is worth asking installers how they sized the system.
How homes are heated
93% of homes use mains gas, so for most households a heat pump would be replacing a gas boiler. Whether that saves money depends heavily on the electricity and gas price gap, the home's insulation and how efficiently the system runs, so compare itemised quotes rather than headline claims.
Among the homes that are not on gas, electric heating is the most common, at 7% of all homes here. Homes on direct electric or storage heating usually see the biggest change in running costs from a heat pump, because the comparison is with full-price electricity.
When homes were built
42% of homes were built between 1930 and 1975. This era is where unfilled cavity walls and thin loft insulation are most common, so insulation upgrades often come before or alongside any change of heating.
Lofts and windows
19% of homes with a roof of their own have no loft or roof insulation recorded, or less than 100 mm. For those homes a top-up to about 270 mm is the usual EPC recommendation.
Almost all homes here are double or triple glazed: 7% have any single glazing recorded.
Energy ratings
Most homes sit in bands C and D, with 17% rated E to G. For those homes the EPC recommendations are a useful check on which upgrades are still outstanding.
Improvements suggested for homes in Erewash
Across the 37,426 certificates here, the improvements suggested most often are solar panels for electricity (83%), solar water heating (71%) and floor insulation (64%).
A heat pump is suggested on fewer than 1% of certificates here, which says more about the assessment software than about the homes.
Ask an installer about solar panels insulation
Heat pump grants in Erewash
142 heat pump installations in Erewash have had a Boiler Upgrade Scheme grant paid (May 2022 to September 2026).
Uptake has grown: 17 grants were paid in 2022/23 and 50 in 2025/26.
These count grant-funded installations only; heat pumps installed without a Boiler Upgrade Scheme grant are not included. Source: DESNZ Boiler Upgrade Scheme statistics.
Installers in and around Erewash
Companies House-registered installers listed for Erewash: 8 installers have their registered office in Erewash, 1 more says on its own website that it works there and 47 more only name the county it is in on their website. 23 of the 56 mention heat pumps.
The typical firm has been trading for 8 years (the median, from Companies House incorporation dates).
The first listed are East Renewables Ltd, LJM Solutions Ltd and T4 Sustainability Limited.
East Renewables Ltd
Says it fits solar PV, battery storage, EV charging
Says it holds MCS
LJM Solutions Ltd
Says it fits solar PV, battery storage, EV charging, boilers
Says it holds MCS, TrustMark, RECC, NAPIT, CHAS, Constructionline
T4 Sustainability Limited
S.h.electrical & Testing Limited
Says it fits solar PV, battery storage
Says it holds RECC, NICEIC
NDL Electrical Installations Ltd
Energised Electrical Contractors Ltd
Eco Switch Improvements Ltd
Sunergy Solar Installs Ltd
Solarsave Ltd
Says it fits solar PV, battery storage, EV charging
Says it holds MCS, RECC, NAPIT
Says it fits air source heat pump, ground source heat pump, hybrid heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers
Says it holds MCS, TrustMark, Gas Safe, Which? Trusted Trader
Alpha Heating (Chesterfield) Limited
Says it fits air source heat pump, solar PV, solar thermal, EV charging, underfloor heating, boilers
Says it holds MCS
Total N.r.g. Limited
Says it fits air source heat pump, ground source heat pump, solar PV, battery storage, underfloor heating, boilers
Says it holds MCS
Says it fits ground source heat pump, air to air heat pump, solar PV, battery storage, EV charging
Says it holds MCS, RECC, Gas Safe
Peak Eco Ltd
Says it fits air source heat pump, ground source heat pump, solar PV, battery storage, underfloor heating
Says it holds MCS
Says it fits air source heat pump, solar PV, battery storage, EV charging
Says it holds MCS, RECC, NICEIC
Renewable Planet Ltd
Says it fits air source heat pump, ground source heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers
Says it holds MCS
Chris Allen Plumbing & Heating Limited
Says it fits air source heat pump, solar PV, battery storage, EV charging, boilers
Says it holds MCS
Henman Dunn Limited
Says it fits air source heat pump, solar PV, battery storage, underfloor heating, boilers
Says it holds MCS, TrustMark, RECC, NAPIT, Gas Safe, OFTEC, APHC, CHAS, Constructionline
Piped Up Ltd
Says it fits air source heat pump, ground source heat pump, solar PV, battery storage, EV charging, boilers
Says it holds MCS
Says it fits air source heat pump, ground source heat pump, air to air heat pump, battery storage, underfloor heating, boilers
Says it holds MCS, TrustMark, HIES
Says it fits air source heat pump, ground source heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers
Says it holds MCS, TrustMark, RECC, NAPIT, Gas Safe, Checkatrade
Says it fits air source heat pump, battery storage, boilers, EV charging, solar PV, solar thermal
Says it holds APHC, HIES, MCS, NAPIT, TrustMark
Says it fits air source heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers
Says it holds MCS, HIES, NICEIC
Their website · More about Renew A Fuel Home Innovations Limited
Says it fits air source heat pump, solar PV, battery storage, EV charging, underfloor heating, boilers, cavity wall insulation, loft insulation, solid wall insulation
Says it holds MCS, TrustMark, RECC, NAPIT, PAS 2035
These are the first 24 of 56: firms that name this area first, then those with a registered office nearby, then those that cover the wider area; heat pump firms and the nearest first within each.
Listed from each firm's own website and from Companies House records (contains public sector information licensed under the Open Government Licence v3.0). Being listed is not a recommendation, and what firms say about themselves has not been checked: ask for an installer's MCS certificate number and consumer code membership before you sign anything.
How Erewash compares with East Midlands
Homes with solid walls are more common here than across East Midlands: 35% of certificates, against 24%.
Advice written for East Midlands as a whole may not fit Erewash on this point.
Grants and support (England)
Boiler Upgrade Scheme: owners of homes in England and Wales, including landlords, can get £7,500 off an air source or ground source heat pump (£2,500 for an air-to-air heat pump) when it replaces fossil fuel heating such as gas, oil, LPG or electric heaters. The installer applies for the grant and it is taken off the price on the quote. Most new builds, social housing and hybrid systems are not eligible, and there is one grant per property.