Homes in Porthcawl (CF36) at a glance
This page summarises 5,514 energy performance certificates (EPCs) for homes in Porthcawl (CF36), using the most recent certificate for each home. 64% are rated D or lower.
The median floor area is about 93 m².
Half of these certificates were issued in 2019 or later, so most describe homes as they are now or were within the last few years.
What kinds of homes are here
Detached and semi-detached homes account for 70% of certificates. These usually have room for an outdoor heat pump unit and a cylinder, but more exposed wall and roof area means insulation quality has a large effect on how well a heat pump performs.
Bungalows are 17% of the sample. They tend to have a large roof area relative to floor area, so loft insulation is usually worth checking first.
Who owns the homes here
Of the certificates that record tenure, 71% are owner-occupied homes, so most upgrade decisions here sit with the people who live in them. 21% are privately rented and 8% socially rented.
Walls and insulation
26% have cavity walls recorded as unfilled or only partly filled. Cavity wall insulation is generally one of the cheaper and less disruptive upgrades, although a survey should confirm the cavity is suitable and not exposed to driving rain or damp problems.
How homes are heated
94% of homes use mains gas, so for most households a heat pump would be replacing a gas boiler. Whether that saves money depends heavily on the electricity and gas price gap, the home's insulation and how efficiently the system runs, so compare itemised quotes rather than headline claims.
Among the homes that are not on gas, electric heating is the most common, at 6% of all homes here. Homes on direct electric or storage heating usually see the biggest change in running costs from a heat pump, because the comparison is with full-price electricity.
When homes were built
47% of homes were built between 1930 and 1975. This era is where unfilled cavity walls and thin loft insulation are most common, so insulation upgrades often come before or alongside any change of heating.
Lofts and windows
30% of homes with a roof of their own have no loft or roof insulation recorded, or less than 100 mm. Loft insulation is usually one of the simpler upgrades, and EPC recommendations work towards about 270 mm. Rooms in the roof and flat roofs are harder and need a closer look.
10% of homes still have some single-glazed windows. In older or listed buildings, secondary glazing is often the permitted option.
Energy ratings
Most homes sit in bands C and D, with 19% rated E to G. For those homes the EPC recommendations are a useful check on which upgrades are still outstanding.
Improvements suggested for homes in Porthcawl (CF36)
Across the 5,514 certificates here, the improvements suggested most often are solar panels for electricity (69%), floor insulation (59%) and solar water heating (48%).
None of the certificates here suggests a heat pump, which says more about the assessment software than about the homes.
Solar water heating is suggested less often here than across Bridgend: on 48% of certificates, against 66%.
Solar panels for electricity is suggested less often here than across Bridgend: on 69% of certificates, against 80%.
Ask an installer about solar panels insulation
Heat pump grants across Bridgend
Boiler Upgrade Scheme figures are published for local authorities, not postcode districts. Across Bridgend, 116 heat pump installations have had a grant paid (May 2022 to September 2026).
Installers in and around Porthcawl (CF36)
Companies House-registered installers listed for Porthcawl: 20 installers have their registered office within 10 miles and 15 more say on their website that they work across Bridgend. 6 of the 35 mention heat pumps.
The typical firm has been trading for 7 years (the median, from Companies House incorporation dates).
The first listed are Gibson Specialist Technical Services Limited, Complete Remedial Solutions (CRS) Ltd and Modern Energy and Electrical Services Ltd.
Says it fits air source heat pump, ground source heat pump, solar PV, solar thermal, battery storage, biomass, boilers, loft insulation, solid wall insulation
Says it holds MCS, NICEIC, Gas Safe, OFTEC, HETAS, Constructionline, ISO 9001
Their website · More about Gibson Specialist Technical Services Limited
Says it fits air source heat pump, solar PV, battery storage, boilers, cavity wall insulation, loft insulation, solid wall insulation
Says it holds MCS, TrustMark, HIES, Gas Safe, CHAS, Constructionline, PAS 2030, PAS 2035
Their website · More about Complete Remedial Solutions (CRS) Ltd
Modern Energy and Electrical Services Ltd
Says it fits solar PV, battery storage
Says it holds MCS, HIES, NAPIT, CHAS
DCN Renewables Limited
Says it fits solar PV, battery storage, EV charging
Says it holds MCS
LMG Home Improvements Limited
Says it fits solar PV, battery storage, EV charging, cavity wall insulation, solid wall insulation
Says it holds MCS, TrustMark, HIES
One Vision Digital Limited
A S Wellington Building and Maintenance Limited
G-LEC Solar Ltd
Surge Electrical Engineering Ltd
MEB Solar/electrical Ltd
Quantum Renewables Ltd
Evergreen Renewable Solutions Ltd
Property Building Maintenance (Wales) Limited
Says it fits EV charging
Says it holds FMB
Bbhs Limited
Hitchings Electrical (Cowbridge) Limited
Cambrian Roofing Ltd
Thermiq Ltd
Ecolec Maintenance Installation Services Ltd
Says it fits EV charging
Sureserve Energy Services Wales Limited
Says it fits solar PV, battery storage, boilers
Says it holds PAS 2030
Prosolar Electrical Ltd
Says it fits air source heat pump, solar PV, battery storage, EV charging
Says it holds MCS, NICEIC, Gas Safe, Constructionline
RHW Renewable Heating Wales Ltd
Says it fits air source heat pump, ground source heat pump, solar PV, battery storage, biomass, underfloor heating, boilers
Says it holds MCS, RECC
Says it fits air source heat pump, ground source heat pump, solar PV, battery storage, EV charging, boilers, cavity wall insulation, loft insulation, solid wall insulation
Says it holds MCS, TrustMark, RECC, Gas Safe, PAS 2030, PAS 2035
Smart Energy Group Ltd
Says it fits air source heat pump, battery storage, boilers, cavity wall insulation, EV charging, loft insulation, solar PV
Says it holds MCS, TrustMark
These are the first 24 of 35: firms that name this area first, then those with a registered office nearby, then those that cover the wider area; heat pump firms and the nearest first within each.
Listed from each firm's own website and from Companies House records (contains public sector information licensed under the Open Government Licence v3.0). Being listed is not a recommendation, and what firms say about themselves has not been checked: ask for an installer's MCS certificate number and consumer code membership before you sign anything.
How Porthcawl (CF36) compares with Bridgend
Flats are more common here than across Bridgend: 29% of certificates, against 15%.
Socially rented homes are less common here than across Bridgend: 8% of certificates, against 20%.
Advice written for Bridgend as a whole may not fit Porthcawl on these points.
Porthcawl (CF36) and its neighbours
Cornelly (CF33) is about 3 miles away. Socially rented homes are more common there: 33% of certificates, against 8% in Porthcawl.
Bridgend (CF31) is about 5 miles away. Flats are less common there: 15% of certificates, against 29% in Porthcawl.
Sarn, Tondu and Bryncethin (CF32) is about 7 miles away. Homes with solid walls are more common there: 39% of certificates, against 19% in Porthcawl.
How Porthcawl (CF36) ranks within Bridgend
Of the 6 Bridgend postcode districts with a page on this site, Porthcawl (CF36) has the highest share of homes with unfilled cavity walls (26%), the highest share of flats (29%) and the lowest share of socially rented homes (8%).
Grants and support (Wales)
The Boiler Upgrade Scheme rules (who qualifies, what it covers and how the installer applies) are summarised on the Bridgend page, with a link to the official GOV.UK guidance.